Firewalls Huawei USG6530E AC Host 10 Puertos GE Wan + 2 Puertos 10GE SFP+,1 Adapter

$2493054
u$s2770
IVA incluído.
Nivel de stock: Disponible
Cod: SBUSG6530E-AC
Agregar al Carrito

Contacta para recibir más información

Tel: 4372-9595 WhatsApp +54 9 11 6 745-9595 
Hasta 12 cuotas sin interés Ver promociones bancarias
Envíos a todo el país Más información
Pick up en tienda Ver ubicación

Firewalls Huawei USG6530E AC Host 10 Puertos GE Wan +2 Puertos 10GE SFP+,1 Adapter Storage Module Micro SD 64GB(SDXC Class 10) Unified Security Gateway License Package IPS-AV-URL-CS License Package Threat Protection Subscription 12 Months (Applies to USG6530E)

Firewalls Huawei USG6510E 

 

 

 

Los firewalls de IA de la serie HiSecEngine USG6500E de Huawei brindan capacidades innovadoras de inteligencia artificial (IA) a pequeñas empresas, ramas de la industria y franquicias. Además de la gestión tradicional de cortafuegos, la gestión en la nube es totalmente compatible, lo que permite que un gran número de sucursales accedan de forma segura a la red y proporciona una serie de ventajas adicionales: implementación plug-and-play, configuración automática de servicios, operaciones y mantenimiento (O&M) visualizados y análisis de big data. El rendimiento de los servicios de detección de seguridad de contenido y seguridad de protocolo de Internet (IPsec) también se mejora significativamente a través de la coincidencia de patrones y el procesamiento acelerado del servicio de cifrado/descifrado.

 

Overview

Table 4-19 Basic information about the USG6525E
Description Part Number Model First supported version
USG6525E AC Host (2*GE WAN+8*GE Combo+2*10GE SFP+,1 AC power) 02353AFX USG6525E-AC V600R007C00
USG6525E AC Host(2*GE WAN+8*GE Combo+2*10GE SFP+,1 AC power) 02353AFX-001 USG6525E-AC V600R007C20SPC500
USG6525E AC Host(2*GE WAN+8*GE Combo+2*10GE SFP+,1 AC power) 02353AFX-002 USG6525E-AC V600R007C20SPC600

Appearance

The two USB ports of earlier-delivered models are USB 3.0 and USB 2.0 respectively, whereas those of later-delivered models are both USB 2.0. In this document, earlier-delivered models are used as examples.

Figure 4-17 Appearance of the USG6525E (front view)
Figure 4-18 Appearance of the USG6525E (rear view)

Components

Figure 4-19 Components of the USG6525E

1. Product series ID

2. Indicator and button area

3. Fixed interface area

4. Protective ground terminal

5. MAC label

6. SN label

7. Fan module

8. Optional power module slot

9. Power module

-

Table 4-20 Component functions

Name

Description

Product series ID

Indicates the product series of the device. For details about the product model, see the nameplate in the lower part of the device.

Indicator and button area

Provides multiple indicators to display the running status of the device in real time and provides the RST button for emergency maintenance.

Fixed interface area

Provides service ports, USB ports, console ports, and out-of-band management ports for device configuration and maintenance.

Protective ground terminal

Connects the M4 OT terminal of a PGND cable to the cabinet or the ground bar in the equipment room.

MAC label

Uniquely identifies the MAC address of the device, which is required during network forwarding configuration.

SN label

Uniquely identifies the device, which needs to be provided for the local technical support personnel to apply for a license.

Fan module

Dissipates heat for the device and is swappable. The fan module can be removed for no more than 1 minute.

The slot number of the fan module is 4.

Power module

Provides power input and distribution for the device. One power module is included in the standard configuration. Two power modules can be configured to achieve 1+1 power redundancy. When one power module is running properly, the other one is hot swappable.

The silkscreens of the power module slots are PWR1 and PWR2, and the corresponding slot numbers are 2 and 3 respectively.

Indicators and Buttons

Figure 4-20 Indicators and buttons on the USG6525E

1. PWR, SYS, USB, HA, WAN and CLOUD indicators

2. GE electrical port ACT indicator

3. GE electrical port LINK indicator

4. Optical port ACT indicator

5. Optical port LINK indicator

6. MGMT port indicator

7. RST button

-

-

-

Arrowheads of optical ports show the positions of the ports. A down arrowhead indicates a port in the upper part, and an up arrowhead indicates a port in the lower part.

Table 4-21 Indicators on the USG6525E
Silkscreen Name Color Status Description
PWR Power indicator Green Steady on The power module is working properly.
- Off The power module is faulty or the device is not powered on.
SYS SYS indicator Green Steady on The system is being powered on or restarted.
Green Blinks once every 2 seconds (0.5 Hz). The system is running normally.
Green Blinking four times every second (4 Hz) The system is starting.
Red Steady on
  • The system is faulty.
  • The power supply is abnormal.
  • The fan module is abnormal.
NOTE:

If the system starts with two power modules and one power module is not powered on, the SYS indicator is steady red, but the system is running properly.

- Off The system is not running.
USB USB indicator Green Steady on USB-based deployment has been completed.
Green Blinking four times every second (4 Hz) The system is reading data from the USB flash drive.
Red Steady on USB-based deployment fails.
- Off USB-based deployment is disabled (default state).
HA HA indicator Green Steady on Hot backup, managing the master device
Green Blinks once every 2 seconds (0.5 Hz). Hot backup, managing the slave device
Red Steady on Dual-system hot backup is faulty.
- Off The dual-system hot backup function is disabled.
WAN WAN indicator - Off Reserved function. This function is not enabled.
CLOUD CLOUD indicator Green Steady on Connected to the cloud management platform.
Green Blinking four times every second (4 Hz) Connecting to the cloud management platform, transmitting or receiving data.
- Off The device is not connected to the cloud management platform.
- ACT indicator of the GE electrical port Yellow Blinking (12 Hz) The port is sending or receiving data.
- Off The port is not sending or receiving data.
- LINK indicator of the GE electrical ports Green Steady on The port link is connected.
- Off No link is established on the port.
- LINK indicator of the optical port Yellow Blinking (12 Hz) The port is sending or receiving data.
- Off The port is not sending or receiving data.
- LINK indicator of an optical port Green Steady on The port link is connected.
- Off No link is established on the port.
- MGMT port indicator Green Steady on The port link is connected.
Green Blinking (12 Hz) The port is sending or receiving data.
- Off No link is established on the port.
Table 4-22 Buttons on the USG6525E
Silkscreen Name Description
RST RST button

To restart the device, press the RST button. Ensure that the running configuration is saved before pressing the RST button.

This button can enable you to restore the default settings with one click. To be specific, you can hold down the RST button for 5 seconds and then release it to restore the default settings and restart the device.

Ports

Figure 4-21 Ports on the USG6525E

1. Combo port

2. 10GE optical port

3. WAN port

4. SSD card slot

5. USB 3.0 port or USB0

NOTE:
  • Earlier-delivered models: USB 3.0
  • Later-delivered models: USB0 (USB 2.0)

6. USB 2.0 port or USB1

NOTE:
  • Earlier-delivered models: USB 2.0
  • Later-delivered models: USB1 (USB 2.0)

7. Console port

8. MGMT port

-

-

Table 4-23 Ports on the USG6525E
Port Connector Type Description Available Components
Combo ports (0 to 7) RJ45 + SFP

Combo ports. Combo ports are logic ports. One combo port can work as a GE electrical interface or a GE optical port. Each combo port has only one internal forwarding port. When the electrical port is enabled, the optical port is disabled. When the optical port is enabled, the electrical port is disabled. The electrical and optical ports of a combo port use the same interface view, numbered from GigabitEthernet 0/0/0 to GigabitEthernet 0/0/7. By default, the combo port is used as an electrical port. You can use the combo enable { copper | fiber } command to set the working mode of combo ports according to network requirements.

NOTE:

Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top.

NOTE:

In V600R007C20SPC500 and later versions, Combo ports support 100Mbps SFP Optical Modules.

10GE optical ports (0 to 1) SFP+

2 10GE optical ports, numbered from XGigabitEthernet 0/0/0 to XGigabitEthernet 0/0/1.

NOTE:

In V600R007C20 and later versions, 10GE optical ports support 1Gbps SFP Copper Modules and 1Gbps eSFP Optical Modules. By default, the rate of 10GE optical ports are 10GE. You can run the set device port-config-mode [ 10ge | ge ] command to set the rate of 10GE optical ports are to 10GE or GE as required.

WAN ports (0 to 1) RJ45

2 10/100/1000M autosensing Ethernet electrical ports, numbered from WAN 0/0/0 to WAN 0/0/1.

The device is connected to the WAN or cloud management center using a network cable.

Ethernet Cable

SSD card slot - The M.2 module is inserted to record logs and reports in real time. The M.2 module is optional. You can purchase the M.2 module as required.
USB 3.0 port or USB0 USB Type A USB port allows you to insert an USB flash drive for system software upgrades. For details on upgrades through USB flash drives, refer to the Upgrade Guide delivered with the device.

USB flash drive

USB 2.0 port or USB1 USB Type A USB ports allow you to insert USB devices for system software upgrades. For details on upgrades through USB devices, refer to the Upgrade Guide delivered with the device.

USB flash drive

Console port RJ45

Console ports allow you to locally connect a PC to the device.

You can use a console cable to connect the console port (RJ45) on the device to the COM port on your PC and use a serial port terminal program on your PC to access, configure, and manage the device.

Console Cable

MGMT port RJ45

Out-of-band 10/100/1000M RJ45 autosensing Ethernet management port. The interface number is METH 0/0/0 and the default IP address of the interface is 192.168.0.1.

You can connect this port to the network port or any reachable port on a PC through a network cable. Then, you can use Telnet to access the CLI or use a web browser to access the web UI to configure, manage, and maintain the device.

NOTE:

The MGMT port cannot be used as a service port.

Ethernet Cable

Power Supply System

  • Early delivery: The power supply system has one PAC60S12-AR, PAC60S12-R, or PAC600S12-CB AC power module. Two power modules can be configured for 1+1 power redundancy.
  • Later delivery: The power supply system has one PAC60S12-AR AC power module. Two power modules can be configured for 1+1 power redundancy.

Heat Dissipation System

The heat dissipation system uses one FAN-023A-B module to dissipate heat for the system. From the front panel, the device provides a front-to-rear air flow. The fan module locates at the air exhaust of the system.

Figure 4-22 System air flow of the USG6525E

 

Technical Specifications

Table 4-24 Technical specifications of the USG6525E
Item Specification
Installation Type
  • Rack
  • Work bench
Cabinet installation standard Cabinet with a depth of 600 mm or above
Dimensions without packaging (H x W x D) [mm(in.)] 43.6 mm x 442 mm x 420 mm (1.72 in. x 17.4 in. x 16.54 in.)
Dimensions with packaging (H x W x D) [mm(in.)] 220 mm x 550 mm x 530 mm (8.66 in. x 21.65 in. x 20.87 in.)
Chassis height [U] 1 U
Weight with packaging [kg(lb)]
  • USG6525E-AC (02353AFX): 8.75 kg (19.29 lb)
  • USG6525E-AC (02353AFX-001): 7.93 kg (17.48 lb)
  • USG6525E-AC (02353AFX-002): 7.93 kg (17.48 lb)
Weight without packaging [kg(lb)]
  • USG6525E-AC (02353AFX): 5.8 kg (12.79 lb)
  • USG6525E-AC (02353AFX-001): 5.95 kg (13.12 lb)
  • USG6525E-AC (02353AFX-002): 5.95 kg (13.12 lb)
CPU 1 CPU, 4 cores/CPU, up to 1.4 GHz
Memory DDR4 4 GB
NOR Flash
  • USG6525E-AC (02353AFX):

    32 MB

    NOTE:

    The NOR flash memory size of devices delivered later is 64 MB. You can run the display version command to check the NOR flash memory size.

  • USG6525E-AC (02353AFX-001):

    32 MB

    NOTE:

    The NOR flash memory size of devices delivered later is 64 MB. You can run the display version command to check the NOR flash memory size.

  • USG6525E-AC (02353AFX-002):

    32 MB

    NOTE:

    The specification of the NOR flash of the device to be delivered is 64 MB. You can run the display version command to view the NOR flash memory specification of a device.

NAND Flash 2 GB
Hard disk Optional. M.2 SSD (64GB/240GB), hot-swappable.
Console port RJ45
Eth Management port RJ45
Maximum power consumption [W]
  • USG6525E-AC (02353AFX): 40 W
  • USG6525E-AC (02353AFX-001): 45.3 W
  • USG6525E-AC (02353AFX-002): 45.3 W
Maximum heat dissipation [BTU/hour]
  • USG6525E-AC (02353AFX): 136.8 BTU/hour
  • USG6525E-AC (02353AFX-001): 154.4 BTU/hour
  • USG6525E-AC (02353AFX-002): 154.4 BTU/hour
MTBF [years] 68.98 years
MTTR [hours] 2 hours
Power supply mode AC built-in
Number of power modules 1
Rated input voltage [V] 100 V to 240 V, 50 Hz/60 Hz
Input voltage range [V] 90 V to 290 V, 47 Hz to 63 Hz
Types of fans Pluggable
Number of fan modules 1
Heat dissipation mode The fan module locates at the air exhaust of the system.
Airflow direction Air inlet from front and air outlet from rear
Redundant power supply Two power modules are supported for 1+1 power redundancy.
Long-term operating temperature [°C(°F)] 0°C to 45°C
Storage temperature [°C(°F)] -40°C to 70°C
Long-term operating relative humidity [RH] 5% RH to 95% RH, non-condensing
Storage relative humidity [RH] 5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)] 0 m to 5000 m
Storage altitude [m(ft.)] 0 m to 5000 m

 

Formulario de contacto